Nordskog
Performance Electronic Gauges are sophisticated instruments that are
highly susceptible to electronic interference. If you are experiencing
problems with your instrument, please check the following before
contacting us:
- Insure
that all grounds are made to the engine block. (Chassis or firewall
grounds are inadequate.)
- Isolate
all grounds from other electronics whenever possible.
- Route
all sensing wires as far away from plug wires and noise generating
wires as possible.
- Use
suppression type plug wires whenever possible.
- Use
twisted shield cable (available from Nordskog) for sensing wires
whenever possible.
- Our
instruments are not guaranteed to function correctly with magnetos and
high energy aftermarket
ignition systems (MSD 7 or above) because of the enormous amount of
interference they can produce.
- Refrain
from using Teflon tape or any other type of sealer on sending unit
threads.
- Check
our website for the latest, up to date instructions.
If
you are still experiencing problems that cannot be solved by one of the
methods listed above, click here to contact us.
|